Megflex Servo Wind Turbine Tray Cable

ELEMENT 1: (See TABLE I)
Bare Copper
Polyester Elastomer, (See Table 1) Diameter
Color Code:
1-3. Black with White Printed Numbers
4. Green/Yellow

ELEMENT 2:
18 AWG (41/34) Bare Copper
Polyester Elastomer, .067" ± .002" Diameter
Color Code: 5-6 Black with White Printed Numbers
Twisted Pair:
Primaries Required: 2
Aluminum/Polyester Tape, 25% Overlap
Braided Shield:
36 AWG Tinned Copper, 65% Coverage
Jacket:
Polyester Elastomer, .012" Wall Thickness
.184" ± .005" Final Diameter
Color: White

ELEMENT 2:
18 AWG (41/34) Bare Copper
Polyester Elastomer, .067" ± .002" Diameter
Color Code: 5-6 Black with White Printed Numbers
Twisted Pair:
Primaries Required: 2
Aluminum/Polyester Tape, 25% Overlap
Braided Shield:
36 AWG Tinned Copper, 65% Coverage
Jacket:
Polyester Elastomer, .012" Wall Thickness
.184" ± .005" Final Diameter
Color: White

OVERALL CABLE:
Element 1: 4 Required
Element 2: 1 Required
* (Alternate Cabling Construction: Add Element 3)
Filler: As Required for Roundness
Expanded Polytetrafluoroethylene Tape, 50% Overlap

BRAIDED SHIELD:
36 AWG Tinned Copper, 85% Coverage (For OD Range .051" - .300")
34 AWG Tinned Copper, 85% Coverage (For OD Range .301" - 1.000")
Polytetrafluoroethylene Tape, 50% Overlap

JACKET:
Separator Tape - Required
C&M Duralon™ (See TABLE 1) Wall Thickness
Final Diameter (See TABLE I)
Color: Black
Print Legend (Green Ink): GreenLINX™ E329622xx AWG 4/C (UL) TYPE WTTC 1000V 90°C FT4 OR TC-ER 600V 90°C FT4 OR c(UL) CIC 90°C DRY FT4 OR AWM 20626--- PREMIUM CONTINOUS FLEX RoHS

Note: xx = AWG

INDUSTRY STANDARD REQUIREMENTS:
RoHS Compliant per European Union Directive 2002/95/EC

SAFETY CERTIFICATIONS: UL Listing: Type TC-ER / WTTC in accordance with Article 336 of the National Electric Code. UL AWM: 20626 90°C 600V

MECHANICAL REQUIREMENTS:
Continuous Flex

  PRIMARY - ELEMENT 1 JACKET - w/ELEMENT 2JACKET- w/ELEMENT 2 & 3
C&M Part #AWG & Standing WallOD Wall Nom ODWall Nom OD

80201

6 (19x35/34)

.022"

.259"

.065"

.850" ± .030"

.065"

.888" ± .030"

80202

8 (7x59/34)

.022"

.211"

.065"

.741" ± .025"

.065"

.796" ± .025"

80203

10 (7x37/34)

.016"

.164"

.065"

.644" ± .020"

.065"

.702" ± .025"

80204

12 (7x24/34)

.011"

.124"

.050"

.527" ± .020"

.050"

.592" ± .020"

80205

14 (105/34)

.011"

.094"

.050"

.461" ± .015"

.050"

.530" ± .020"

80206

16 (65/34)

.011"

.081"

.050"

.426" ± .015"

.050"

.504" ± .020"

♦ Tested to 20 million cycles
♦ When ordering the C&M Product, use the individual part number followed by a -1 (i.e. xxxxx-1 = 1 Pair) or -2 (i.e. xxxxx-2 = 2 Pair) to indicate preferred construction type.